Hall current sensors are mainly used to isolate and convert AC, DC, pulse and other complex signals .After signals are convertedaccording to the Hall Effect Theory,the can be directly acquired by AD, DSP, PLC, secondary instruments and other devices.
Electrical characteristics | |||||||
Type | CS100EKG | CS200EKG | CS300EKG | CS500EKG | CS600EKG | ||
IPN | Primary nominal input current | 100 | 200 | 300 | 500 | 600 | A |
IP | Measuring range of primary current | 0~±200 | 0~±400 | 0~±600 | 0~±1000 | 0~±1200 | A |
VOUT | Nominal output voltage | 4(±1%) | V | ||||
VC | Supply voltage | ±12~±15(±5%) | V | ||||
IC | Current consumption | 25 | mA | ||||
Vd | Insulation voltage | AC/50Hz/1min 3.0 | kV | ||||
εL | Linearity | ±1 | %FS | ||||
V0 | Offset voltage | TA =25℃ 25 | mV | ||||
VOM | Residual voltage | IPN→0 <±20 | mV | ||||
VOT | Thermal drift of V0 | IPN=0 TA =-25~+85℃ <±1 | mV/℃ | ||||
Tr | Response time | ≤7 | μs | ||||
f | Frequency bandwidth(-3dB) | DC~20 | kHz | ||||
TA | Ambient operating temperature | -25~+85 | ℃ | ||||
TS | Ambient storage temperature | -40~+100 | ℃ | ||||
RL | Load resistance | ≥10K | Ω | ||||
m | Mass | 50 | g | ||||
Standard | Q/320115QHKJ01-2010 | ||||||