Nanjing Chieful Science & Technology Co., Ltd.

Nanjing Chieful Science & Technology Co., Ltd.

Manufacturer from China
Active Member
7 Years
Home / Products / Hall Effect Current Transducer /

Black Open Loop Hall Current Transducer With Strong Anti-Jamming Capability

Contact Now
Nanjing Chieful Science & Technology Co., Ltd.
City:nanjing
Province/State:jiangsu
Country/Region:china
Contact Person:MsLi Ting
Contact Now

Black Open Loop Hall Current Transducer With Strong Anti-Jamming Capability

Ask Latest Price
Video Channel
Place of Origin :Jiangsu, China (Mainland)
Brand Name :chieful
Model Number :CS800F
MOQ :1 Piece
Price :Negotiable
Usage :Magnetic Sensor
Theory :Hall Sensor
Output :Analog Sensor
color :black
weight :224g
window size :41*12mm
Selling Units :Single item
Single package size  :23X18X7 cm
Single gross weight :0.224 kg
Package Type :packing in bubble and carton
more
Contact Now

Add to Cart

View Product Description
Black Open Loop Hall Current Transducer With Strong Anti-Jamming Capability

open loop hall current transducer CS800F

Features:
Easy installation
No insertion loss
Strong anti-jamming capability
Small size, saving space
Good linearity
Low temperature drift
High precision
Fast response time
open loop current sensor develops on based on the measuring principle of the hall effect, with a galvanic isolation between primary and secondary circuit. It provides accurate electronic measurement of DC, AC or pulsed currents without insert loss.
Electrical characteristics
Type CS100F CS200F CS400F CS600F CS800F CS1000F
IPN Primary nominal input current 100 200 400 600 800 1000 A
IP Measuring range of primary current 0~±200 0~±400 0~±800 0~±1200 0~±1600 0~±2000 A
VOUT Nominal output voltage 4(±1%) V
VC Supply voltage ±12~±15(±5%) V
IC Current consumption 25 mA
Vd Insulation voltage AC/50Hz/1min 3.0 kV
εL Linearity ±1 %FS
V0 Offset voltage TA =25℃ 25 mV
VOM Residual voltage IPN→0 <±20 mV
VOT Thermal drift of V0 IPN=0 TA =-25~+85℃ <±1 mV/℃
Tr Response time ≤7 μs
f Frequency bandwidth(-3dB) DC~20 kHz
TA Ambient operating temperature -25~+85
TS Ambient storage temperature -40~+100
RL Load resistance ≥10K Ω
m Mass 50 g
Standard Q/3201CHGL02-2007
Dimensions of drawing (mm)

About us

CHIEFUL offers a wide range of current and voltage transducers in the portfolio. And our transducer can be designed according to the specific demands.The company explore foreign markets actively, our products have been sold to the United Kingdom, Germany, Denmark, France, Italy, Sweden,Turkey, Israel, South Korea, India etc.

Exhibition

Logistics packaging

FAQ

Q1: Are you a factory?
A:We are a factory setted up more than 17 years and export more than 10years.

Q2: When is the delivery date?
A: 7-10 working days in general.

Q3: Could you send me a quotation?
A: Sure.

Q4: How about the after service?
A: Five years warranty.

Q5: What about the shipping package?
A: Anti-static package and carton.

Inquiry Cart 0
You May Like
Easy Install Hall Effect Current Sensor with 8 x 12 mm Window size CE Rohs
Easy Install Hall Effect Current Sensor with 8 x 12 mm Window size CE Rohs
AC DC Hall Effect Current Sensor Open Loop Mode With 600A Input Current
AC DC Hall Effect Current Sensor Open Loop Mode With 600A Input Current
Hall Effect Current Transducer Open Loop RoHS And CE Verified CS600K
Hall Effect Current Transducer Open Loop RoHS And CE Verified CS600K
Open Loop Measuring Hall Effect Current Transducer Good Linearity CS050EK1
Open Loop Measuring Hall Effect Current Transducer Good Linearity CS050EK1
Welding Machine Hall Effect Precision Current Transducer 4V Output Window 22 X16mm
Welding Machine Hall Effect Precision Current Transducer 4V Output Window 22 X16mm
Hall Effect Current Transducer Closed Loop Type Window Size 12.5 X 7 Mm
Hall Effect Current Transducer Closed Loop Type Window Size 12.5 X 7 Mm
Accuracy Magnetic Hall Effect AC Current Transducer Analog Output A-CS050GET
Accuracy Magnetic Hall Effect AC Current Transducer Analog Output A-CS050GET
Open Loop Hall Effect Current Transducer for UPS Servo Control Systems
Open Loop Hall Effect Current Transducer for UPS Servo Control Systems
Open Loop Type Hall Effect Current Transducer 500A Input 20mm Diameter
Open Loop Type Hall Effect Current Transducer 500A Input 20mm Diameter
High Reliability Hall Effect Closed Loop Current Transducer CE Approved CSM050LX
High Reliability Hall Effect Closed Loop Current Transducer CE Approved CSM050LX
CE Rohs Open Loop Hall Effect Current Transducer For DC Motor Drive System
CE Rohs Open Loop Hall Effect Current Transducer For DC Motor Drive System
Open Loop Hall Effect Current Transducer 4V Output For Welding Machines
Open Loop Hall Effect Current Transducer 4V Output For Welding Machines
Split Core Hall Effect Current Transducer Open Loop 4V Output CS600EKG
Split Core Hall Effect Current Transducer Open Loop 4V Output CS600EKG
Easy Install Hall Effect Current Sensor with 8 x 12 mm Window size CE Rohs
Easy Install Hall Effect Current Sensor with 8 x 12 mm Window size CE Rohs
AC DC Hall Effect Current Sensor Open Loop Mode With 600A Input Current
AC DC Hall Effect Current Sensor Open Loop Mode With 600A Input Current
Send your message to this supplier
*From:
*To:

Nanjing Chieful Science & Technology Co., Ltd.

*Subject:
*Message:
Characters Remaining : (0/3000)
Contact Now